Class 600 Studding Outlets

01

Flat Bottom

Flat Bottom
02

Shell Or Head Mount

Shell Or Head Mount
03

Tangential Mount

Tangential Mount
Bore OD Thickness OD of RF Stud Circle Hole Dia # of Holes Hole Depth Tap Size T.P.I. Tap Depth Flat Bottom Weight
B O T R C U V Base per 1″
 1/2 3.75 1.50 1.38 2.62 27/64 4 0.88  1/2 13 0.56 3.8 3.1
 3/4 4.62 1.75 1.69 3.25 17/32 4 1.12  5/8 11 0.75 6.7 4.6
1 4.88 1.75 2 3.5 17/32 4 1.12  5/8 11 0.75 7.4 5.1
1 1/4 5.25 1.75 2.5 3.88 17/32 4 1.12  5/8 11 0.75 8.6 5.8
1 1/2 6.12 1.94 2.88 4.5 21/32 4 1.31  3/4 10 0.88 13 7.8
2 6.5 1.75 3.62 5 17/32 8 1.12  5/8 11 0.75 12 8.5
2 1/2 7.5 2.00 4.12 5.88 21/32 8 1.31  3/4 10 0.88 19 11
3 8.25 2.00 5 6.62 21/32 8 1.31  3/4 10 0.88 23 13
3 1/2 9 2.12 5.5 7.25 49/64 8 1.44  7/8 9 1.00 28 15
4 10.75 2.12 6.19 8.50 49/64 8 1.44  7/8 9 1.00 41 22
5 13 1.25 7.31 10.50 7/8 8 1.56 1 8 1.12 63 32
6 14 2.25 8.5 11.50 7/8 12 1.56 1 8 1.12 68 36
8 16.5 2.50 10.62 13.75 1 12 1.81 1 1/8 8 1.25 101 46
10 20 2.75 12.75 17 1  1/8 16 2.12 1 1/4 8 1.44 160 67
12 22 2.75 15 19.25 1  1/8 20 2.12 1 1/4 8 1.44 180 76
14 23.75 2.88 16.25 20.75 1  1/4 20 2.25 1 3/8 8 1.56 201 82
16 27 3.00 18.5 23.75 1  3/8 20 2.38 1 1/2 8 1.69 271 105
18 29.25 3.25 21 25.75 1  1/2 24 2.56 1 5/8 8 1.88 331 118
20 32 3.25 23 28.50 1  1/2 24 2.56 1 5/8 8 1.88 387 139
24 37 3.75 27.25 33 1  3/4 24 3.00 1 7/8 8 2.12 571 176

Dimensions are in inches. Weights are in pounds.

Thickness: The standard thickness shown above for all studding outlets is the minimum required per ASME Section VIII Division I Paragraph UG-43(d) for thread engagement and an ID mount. It is important to note that each individual application should be analyzed for proper thickness.

Facing: The Studding Outlet minimum thickness “T” includes proper raised face per ANSI B16.5. Outlets can be supplied with any special facing as needed upon request.

Drilling and Tapping: Studding Outlets are furnished to ANSI B16.5 specifications unless otherwise specified. Thread depth is in accordance with ASME Section VIII Division I Para. UG-43(g) for a design temperature not to exceed 650ºF, a base metal stress of 17,500 psi(g), and a stud stress of 25,000 psi(g). All other materials exceeding these stresses should be checked for UG-43 compliance.

Bore: Bore sizes shown above are standard. Other sizes can be furnished upon request.

Curving: Connections can be furnished contoured to fit any shell, head, or cone at additional cost. Specify diameter to be mounted.

The Parts You Need, When You Need Them

Since 1986, Texas Flange has delivered precision Flange solutions with speed, affordability, and expertise. Let’s discuss your project today!

flange-basis